Module Name
Lenel OnGuard Access Control Cryptographic Module
Historical Reason
Moved to historical list due to dependency on certificate #2606
Caveat
When operated in FIPS mode with Cryptographic Primitives Library (bcryptprimitives.dll and ncryptsslp.dll) in Microsoft Windows 10, Windows 10 Pro, Windows 10 Enterprise, Windows 10 Enterprise LTSB, Windows 10 Mobile, Windows 10 for Surface Hub validated to FIPS 140-2 under Cert. #2606 operating in FIPS mode or Cryptographic Primitives Library (bcryptprimitives.dll and ncryptsslp.dll) in Microsoft Windows 10, Windows 10 Pro, Windows 10 Enterprise, Windows 10 Enterprise LTSB, Windows 10 Mobile, Windows Server 2016 Standard, Windows Server 2016 Datacenter, Windows Storage Server 2016 validated to FIPS 140-2 under Cert. #2937 operating in FIPS mode
Security Level Exceptions
- Physical Security: N/A
- Design Assurance: Level 3
- Mitigation of Other Attacks: N/A
Embodiment
Multi-Chip Stand Alone
Description
Lenel open platform security system integrates seamlessly with video, intrusion, access and fire products and offers remote access and management functionality, and is constantly evolving to meet changing mandates and guidelines. FICAM Architecture options include
onboard authentication, ideal for new installations, or an add-on authentication module, perfect for retrofits and architectures where onboard authentication is not available. The OnGuard FICAM security management solution consists of Lenel OnGuard software, Lenel
access and door controllers, and HID pivCLASS® software and readers.
Tested Configuration(s)
- Microsoft Windows 10 64-bit running on Precision Workstation T3500 with an Intel Xeon W3670
- Microsoft Windows Server 2016 64-bit running on Precision Workstation T3500 with an Intel Xeon W3530 (single-user mode)
Allowed Algorithms
NDRNG; RSA (key wrapping; key establishment methodology provides between 112 and 150 bits of encryption strength)
Software Versions
7.4.457.69 with Critical On-Demand Hot Fix for DE40714 or 7.5.375.1